Outdoor Unit Specifications
Type |
Outdoor Unit |
Unit |
Heat Pumps |
Performance & Electrical Ratings |
|
Capacity Cooling (Btu/h) |
29,000 / 28,600 |
Capacity Heating (Btu/h) |
30,600 |
Air Circulation (High) Cooling CFM |
1,942 |
Number of Connectable Indoor Units |
2 ~ 4 |
SEER - Cooling |
17.2 |
EER - Cooling |
11.2 |
HSPF - Heating |
9.3 |
Power Supply V, Phase, Hz |
230V / 208V, 1Ph, 60Hz |
Running Ampere - A |
Cooling: 11.4 / 12.6 |
|
Heating: 10.1 / 11.2" |
Power Input - W |
Cooling: 2,600 / 2,560 |
|
Heating: 2,300 |
Maximum Fuse Size - Amps |
20A |
Features |
|
Controls |
Microprocessor |
Fan Speeds |
Auto (Hi, Me, Lo) |
Compressor |
DC Inverter |
Refrigerant / Amount Charged at Shipment 1b. |
R-410A / 6.17 |
Refrigerant Control |
Electric Expansion Valve |
Operating Sound (Hi) - dB-A |
Cooling: 53 |
|
Heating: 55 |
Refrigerant Tube Connections - Type |
Flare |
Max. Allowable Tubing Length Ft |
100 (per Unit) 230 (per System with additional Refrigerant) |
Refrigerant Tube Diameter - Narrow Tube - inches |
1/4" x 4 |
Refrigerant Tube Diameter - Wide Tube - inches |
3/8" x 2 + 1/2" x 2 |
Dimensions & Weight |
|
Height (inches) |
35-1/32" |
Width (inches) |
35-7/16" |
Depth (inches) |
12-19/32" |
Net Weight (lbs.) |
181 |
Indoor Unit Specifications:
CS-MKE18NKU
Type |
Wall Mounted |
Unit |
Heat Pumps |
Power Source |
230V-208V, 1 PH, 60 Hz |
Running Ampere - A |
0.15 / 0.17 |
Power Input - W |
35 |
Capacity Cooling (Btu/h) |
17,500 |
Capacity Heating (Btu/h) |
20,400 |
Moisture Removal - High - Pints/H |
4.89 |
Dimensions & Weight |
|
Height (inches) |
11"-23/32" |
Width (inches) |
41"-15/16" |
Depth (inches) |
8"-19/32" |
Net Weight (lbs.) |
26.5 |
Air Circulation (H.M.L) Cooling CFM |
500 / 447 / 377 |
Air Circulation (H.M.L) Heating CFM |
500 / 447 / 377 |
Operating Sound (H/L) Cooling - dB-A |
41 / 38 / 34 / 28 |
Operating Sound (H/L) Heating - dB-A |
40 / 37 / 34 / 28 |
Refrigerant Tube Diameter - Narrow Tube - inches |
1/4" |
Refrigerant Tube Diameter - Wide Tube - inches |
1/2" |
Elevation Difference - Outdoor Above - ft |
Max. 50* |
* This is maximum elevation difference when the indoor unit is located above the outdoor unit. |
|
Elevation Difference - Outdoor Below - ft |
Max. 50* |
* This is maximum elevation difference when the indoor unit is located above the outdoor unit. |
CS-MKE24NKU
Type |
Wall Mounted |
Unit |
Heat Pumps |
Power Source |
230V-208V, 1 PH, 60 Hz |
Running Ampere - A |
0.20 / 0.22 |
Power Input - W |
45 |
Capacity Cooling (Btu/h) |
24,200 |
Capacity Heating (Btu/h) |
29,000 |
Moisture Removal - High - Pints/H |
4.89 |
Dimensions & Weight |
|
Height (inches) |
11"-23/32" |
Width (inches) |
41"-15/16" |
Depth (inches) |
8"-19/32" |
Net Weight (lbs.) |
26.5 |
Air Circulation (H.M.L) Cooling CFM |
541 / 500 / 435 |
Air Circulation (H.M.L) Heating CFM |
541 / 500 / 435 |
Operating Sound (H/L) Cooling - dB-A |
44 / 41 / 38 / 30 |
Operating Sound (H/L) Heating - dB-A |
43 / 40 / 37 / 30 |
Refrigerant Tube Diameter - Narrow Tube - inches |
1/4" |
Refrigerant Tube Diameter - Wide Tube - inches |
5/8" |
Elevation Difference - Outdoor Above - ft |
Max. 50* |
* This is maximum elevation difference when the indoor unit is located above the outdoor unit." |
|
Elevation Difference - Outdoor Below - ft |
Max. 50* |
* This is maximum elevation difference when the indoor unit is located above the outdoor unit." |